Low Torque Indicating Ratchet Wrench

Accurately Assess Torque

The Solution Designed To Provide Clinicians With Consistent Low Torque Assessment

  • The Low Torque Indicating Ratchet Wrench (L-TIRW) is a unique low torque ratchet wrench designed for restorative dentistry.
  • The Low Torque Indicating Ratchet Wrench is sleek and easy to use, providing clinicians with an option they may not have had before: an inexpensive instrument that provides accurate low torque assessment when placing restorative components.
  • The Low Torque Indicating Ratchet Wrench (L-TIRW) indicates forward and reverse torque of up to 35 Ncm without the need for additional components.
Low Torque Indicating Ratchet Wrench

Versatile Solutions for Patients Who Demand More Choices and Faster Results

Screw Removal Tool Kits

The Right Tools For A Rare Occasion

ZimVie Dental Screw Removal Tools Kit facilitates the removal of a broken screw from the internal threads of Certain and External Hex Implants in the unlikely event of a screw fracture below the occlusal surface of the dental implant.

  • Remove And Retrieve - A restorative solution designed to extract broken abutment screws in the unlikely event of dental screw fracture.
  • Design Precision - Increase the odds of rescuing the fractured dental screw with tools specifically designed and manufactured for Certain and External Hex Dental Implant Systems.
  • Convenience - Each kit contains all necessary parts to facilitate dental screw removal, or tools can be purchased individually.
ZimVie Dental Implant Screw Removal Kit

Abutments Screws

Gold-Tite® Screw and SureSeal® Technology

SureSeal Technology shall be designed for superior seal integrity through the Implant-Abutment Junction (IAJ). This shall be achieved with the combination of the proprietary Gold-Tite Screw, Certain Internal Connection and precision manufacturing processes.

Implant-Abutment Seal Strength with the Gold-Tite Screw

  • Peri-implant Mucositis - The prevalence of peri-mucositis has been reported as high as 80% of all dental patients.1
  • Peri-implantitis - The prevalence of implants experiencing peri-implantitis has been reported in excess of 12%.2,3
  • Crestal Bone Loss - Average implant crestal bone remodeling can exceed 1.5 mm following the first year of function, leading to compromised aesthetics.3
  • Implant/abutment seal strength - Use of the Gold-Tite Screw increases Certain Implant/abutment clamping force by up to 113% as compared to a non-coated titanium alloy screw.
ZimVie Implant-Abutment Seal Strength with the Gold-Tite Screw

Three Simple Steps to Better Dental Care